top of page
Huawei S310-24P4X Switch (24*GE ports(400W PoE+), 4*10GE SFP+ ports, built-in AC

Huawei S310-24P4X Switch (24*GE ports(400W PoE+), 4*10GE SFP+ ports, built-in AC

EGP27,650.00 Regular Price
EGP27,300.00Sale Price

Huawei S310-24P4X  Switch  (24*GE ports(400W PoE+), 4*10GE SFP+ ports, built-in AC power)

Quantity
  • Description

    S310-24P4X

  • Overview

    Description S310-24P4X (24*10/100/1000BASE-T ports(400W PoE+), 4*10GE SFP+ ports, built-in AC power)
    Part Number 98012382
    Model S310-24P4X
    First supported version V600R023C00
    Technical Specifications
    Dimensions without packaging (H x W x D) [mm(in.)] Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.66 in.)
    Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 227.0 mm (1.72 in. x 17.4 in. x 8.94 in.)
    Dimensions with packaging (H x W x D) [mm(in.)] 90.0 mm x 550.0 mm x 360.0 mm (3.54 in. x 21.65 in. x 14.17 in.)
    Chassis height [U] 1
    Chassis material Metal
    Weight without packaging [kg(lb)] 2.92 kg (6.44 lb)
    Weight with packaging [kg(lb)] 3.79 kg (8.36 lb)
    Typical power consumption [W] 37.12
    Typical heat dissipation [BTU/hour] 126.65
    Maximum power consumption [W] – Without PoE: 44.35 W
    – Full PoE load: 485.91 W (PoE: 400 W)
    Maximum heat dissipation [BTU/hour] – Without PoE: 151.32
    – Full PoE load: 1657.92
    Static power consumption [W] 27.07
    MTBF [years] 60.18
    MTTR [hours] 2
    Availability > 0.99999
    Noise at normal temperature (acoustic power) [dB(A)] 49.3
    Noise at normal temperature (acoustic pressure) [dB(A)] 37.3
    Number of card slots 0
    Number of power slots 0
    Number of fans modules 2
    Redundant power supply Not supported
    Long-term operating temperature [°C(°F)] -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5905.44 ft.)
    Restriction on the operating temperature variation rate [°C(°F)] When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).
    Devices cannot start when the temperature is lower than 0°C (32°F).
    Storage temperature [°C(°F)] –40°C to +70°C (–40°F to +158°F)
    Long-term operating relative humidity [RH] 5% RH to 95% RH (non-condensing)
    Long-term operating altitude [m(ft.)] 0–5000 m (0–16404 ft.)
    Storage altitude [m(ft.)] 0-5000 m (0-16404 ft.)
    Power supply mode AC built-in
    Rated input voltage [V] – AC input: 100 V AC to 240 V AC, 50/60 Hz
    – High-voltage DC input: 240 V DC
    Input voltage range [V] – AC input: 90 V AC to 290 V AC; 45 Hz to 65 Hz
    – High-voltage DC input: 190 V DC to 290 V DC
    Maximum input current [A] 6 A
    Memory 2 GB
    Flash memory Physical space: 1 GB
    Console port RJ45
    Eth Management port Not supported
    USB Not supported
    RTC Not supported
    RPS input Not supported
    Service port surge protection [kV] Common mode: ±7 kV
    Power supply surge protection [kV] Differential mode: ±6 kV; common mode: ±6 kV
    Ingress protection level (dustproof/waterproof) IP20
    Types of fans Built-in
    Heat dissipation mode Air cooling for heat dissipation, intelligent fan speed adjustment
    Airflow direction Air intake from left and front, air exhaustion from right
    PoE Supported
    Certification EMC certification
    Safety certification
    Manufacturing certification

     

     

bottom of page